Abstract:

The experiments on reactance compensation of the reflection type of cavity masers were brought to a successful conclusion. The measurements to determine optimum ruby concentration and the results obtained by using the double-cavity technique are described. Parallel experiments on unilateral broadband masers of the transmission type containing circularly polarized cavities have still not developed a converging adjustment procedure for the excessive number of interacting tuning parameters. There is still much engineering work to be done before the system can be used reliably as a part of a radio astronomy telescope or a supersensitive laboratory spectrograph. A bandwidth greater than 100 mc is obtained with a single ruby cavity. Author