Accession Number : ADA528437


Title :   Biological Variation and Diagnostic Accuracy of Dehydration Assessment Markers


Descriptive Note : Journal article


Corporate Author : ARMY RESEARCH INST OF ENVIRONMENTAL MEDICINE NATICK MA THERMAL AND MOUNTAIN MEDICINE DIVISION


Personal Author(s) : Cheuvront, Samuel N ; Ely, Brett R ; Kenefick, Robert W ; Sawka, Michael N


Full Text : https://apps.dtic.mil/dtic/tr/fulltext/u2/a528437.pdf


Report Date : Jul 2010


Pagination or Media Count : 10


Abstract : Well-recognized markers for static (one time) or dynamic (monitoring over time) dehydration assessment have not been rigorously tested for their usefulness in clinical, military, and sports medicine communities. This study evaluated the components of biological variation and the accuracy of potential markers in plasma, urine, saliva, and body mass (Bm) for static and dynamic dehydration assessment. Design: We studied 18 healthy volunteers (13 men and 5 women) while carefully controlling hydration and numerous preanalytic factors. Biological variation was determined over 3 consecutive days by using published methods. Atypical values based on statistical deviations from a homeostatic set point were examined. Measured deviations in body fluid were produced by using a separate, prospective dehydration experiment and evaluated by receiver operating characteristic (ROC) analysis to quantify diagnostic accuracy. Results: All dehydration markers displayed substantial individuality and one-half of the dehydration markers displayed marked heterogeneity of intraindividual variation. Decision levels for all dehydration markers were within one SD of the ROC criterion values, and most levels were nearly identical to the prospective group means after volunteers were dehydrated by 1.8-7.0% of Bm. However, only plasma osmolality (Posm) showed statistical promise for use in the static dehydration assessment. A diagnostic decision level of 301 plus or minus 5 mmol/kg was proposed. Reference change values of 9 mmol/kg (Posm), 0.010 [urine specific gravity (Usg)], and 2.5% change in B(m) were also statistically valid for dynamic dehydration assessment at the 95% probability level.


Descriptors :   *MONITORING , *DIAGNOSIS(MEDICINE) , *DEHYDRATION , STATISTICS , ACCURACY , VARIATIONS , MEDICINE , MARKERS , VALUE , BODY FLUIDS , URINE , BLOOD PLASMA , HOMEOSTASIS , BIOLOGY , SALIVA , REPRINTS , OSMOSIS


Subject Categories : Medicine and Medical Research


Distribution Statement : APPROVED FOR PUBLIC RELEASE