Accession Number : ADA281354


Title :   Basewide Groundwater Operable Unit. Groundwater Operable Unit Remedial Investigation/Feasibility Study Report. Volume 1


Descriptive Note : Final rept.


Corporate Author : CH2M HILL SACRAMENTO CA


Full Text : https://apps.dtic.mil/dtic/tr/fulltext/u2/a281354.pdf


Report Date : Jun 1994


Pagination or Media Count : 729


Abstract : This document presents the Remedial Investigation/Feasibility Study (RI/FS) for the Groundwater Operable Unit (GW OU) at McClellan Air Force Base (McClellan AFB). The RI/FS is one step in the GW OU, which is intended to develop an interim remedial action for groundwater contamination at McClellan AFB. The preferred interim remedial action for the GW OU is containment of the 0.000006 risk target volume, treatment using air stripping with vapor phase carbon and LGAC polishing on the east side, the existing GWTP on the west side, and injection of the treated water.


Descriptors :   *WATER POLLUTION ABATEMENT , *WATER TREATMENT , *INSTALLATION RESTORATION , *GROUND WATER , METALS , FEASIBILITY STUDIES , CALIFORNIA , SOIL POLLUTION , CONTAMINATION , HAZARDOUS MATERIALS , WATER WELLS , WATER QUALITY , HAZARDOUS WASTES , WASTE DISPOSAL , AIR FORCE FACILITIES , SOLVENTS , WATER FLOW , DRINKING WATER , PERMEABILITY


Subject Categories : Hydrology, Limnology and Potamology
      Logistics, Military Facilities and Supplies
      Water Pollution and Control


Distribution Statement : APPROVED FOR PUBLIC RELEASE