Accession Number : ADA258347


Title :   High-Altitude Electromagnetic Pulse Survivability Assessment of the Harris RF-3200 Transceiver.


Descriptive Note : Final rept. 1 Oct 1989-1 Oct 1991,


Corporate Author : HARRY DIAMOND LABS ADELPHI MD


Personal Author(s) : Coburn, William O ; Nguyen, Eric ; Reyzer, Ronald J ; Mar, Mark H


Full Text : https://apps.dtic.mil/dtic/tr/fulltext/u2/a258347.pdf


Report Date : Sep 1992


Pagination or Media Count : 104


Abstract : Harry Diamond Laboratories conducted a high-altitude electromagnetic pulse (HEMP) survivability/vulnerability assessment of a high-frequency transceiver system, the Harris Corporation RF-3200 transceiver and ancillary equipment. The non-developmental item and a hardened version of the RF-3200 system were both HEMP simulation tested. External transient protection devices were HEMP hardened at the various system electrical interfaces. The test and analysis results establish the RF-3200 transceiver system survivability when it is exposed to a HEMP threat environment.


Descriptors :   *TRANSMITTER RECEIVERS , *ELECTROMAGNETIC PULSES , *ELECTROMAGNETIC PULSE SIMULATORS , TEST AND EVALUATION , FREQUENCY , SIMULATORS , SIMULATION , TRANSIENTS , HIGH FREQUENCY , ENVIRONMENTS , CORPORATIONS , SURVIVABILITY , THREATS , INTERFACES , DIAMONDS , PULSES , HIGH ALTITUDE , PROTECTION , LABORATORIES , EXTERNAL , ALTITUDE


Subject Categories : Electrical and Electronic Equipment
      Electromagnetic Pulses


Distribution Statement : APPROVED FOR PUBLIC RELEASE