Accession Number : ADA256466


Title :   Output Frequency Changes in a Commercial Rubidium Clock Resulting from Magnetic Field and Microwave Power Variations


Descriptive Note : Master's thesis


Corporate Author : AIR FORCE INST OF TECH WRIGHT-PATTERSON AFB OH SCHOOL OF ENGINEERING


Personal Author(s) : Sarosy, Edward B


Full Text : https://apps.dtic.mil/dtic/tr/fulltext/u2/a256466.pdf


Report Date : Sep 1992


Pagination or Media Count : 103


Abstract : This report shows the relationship between output frequency shifts and the absorption cell magnetic field during microwave power fluctuations on a commercial rubidium frequency clock. Changes in the clock output frequency relative to the 10 MHz reference were monitored as changes in the absorption cell magnetic field (0.01 to 1.0 Gauss) and changes in the cell's interrogation microwave power were varied from the nominal specification (PO) at four discrete values (+1.3. -1.1, -2.2, -4.OdB). The maximum normalized output frequency shift of 1.4xlO- 10 occurred at--4dB. The maximum normalized frequency change for the +1.3 and -1.1 dB data is about 3 x 10-11, and for the -2.2 dB data is about 6 x 10-11. As a function of the change in microwave power, the maximum frequency change is about 2.6 x 10- -per dB of power change. There also existed several magnetic field values which resulted in minimum output frequency change. This occurred at absorption cell magnetic field values of 9 and 27 milli-Gauss, where the nominal setting is 137 milli-Gauss. RUBIDIUM HYPERFINE ENERGY LEVELS.


Descriptors :   *RUBIDIUM , *FREQUENCY SHIFT , *ZEEMAN EFFECT , *ATOMIC CLOCKS , *MICROWAVE SPECTROSCOPY , FREQUENCY , OUTPUT , FUNCTIONS , MAGNETIC FIELDS , CLOCKS , SPECIFICATIONS , CELLS , ENERGY , HYPERFINE STRUCTURE , THESES , MICROWAVES , POWER , VALUE , ABSORPTION , INTERROGATION , ENERGY LEVELS


Subject Categories : Test Facilities, Equipment and Methods
      Atomic and Molecular Physics and Spectroscopy


Distribution Statement : APPROVED FOR PUBLIC RELEASE