Accession Number : ADA254941


Title :   A Heat Pipe Coupled Planar Thermionic Converter: Performance Characterization, Nondestructive Testing, and Evaluation.


Descriptive Note : Final rept. 1 Aug 1990-30 Nov 1991,


Corporate Author : WRIGHT LAB WRIGHT-PATTERSON AFB OH


Personal Author(s) : Young, Timothy J ; Lamp, Thomas R ; Tsao, Bang-Hung ; Ramalingam, Mysore L


Full Text : https://apps.dtic.mil/dtic/tr/fulltext/u2/a254941.pdf


Report Date : 15 Mar 1992


Pagination or Media Count : 119


Abstract : This report provides the technical details on the research activities conducted by Wright Laboratory and UES, Inc. personnel during the period of August 1990 to November 1991. The performance of two heat pipe coupled, planar thermionic energy converters was characterized using experimental and analytical methods. Nondestructive failure analysis was performed to evaluate the causes for the failure of a molybdenum-rhenium converter. The experimentation was carded out at the thermionic facilities at the USAF Wright Laboratory while the computer simulations were performed at Wright Laboratory and the University of Central Florida. A maximum current density of 10.1 amps/cm2 and a peak power density of 7.7 watts/cM2 were obtained from the rhenium-rhenium diode operating in the ignited mode.


Descriptors :   *HEAT PIPES , DIODES , SIMULATION , DENSITY , NONDESTRUCTIVE TESTING , COMPUTERS , FACILITIES , ENERGY , FAILURE , CURRENT DENSITY , MOLYBDENUM , CESIUM , PIPES , PEAK POWER , LABORATORIES , PERSONNEL , POWER , TOMOGRAPHY , RHENIUM , HEAT , FLORIDA , RESERVOIRS , CONVERTERS


Subject Categories : Thermodynamics


Distribution Statement : APPROVED FOR PUBLIC RELEASE