Accession Number : ADA169492


Title :   Ion Acoustic Microscopy


Descriptive Note : Final rept. Jul 1983-Jun 1984


Corporate Author : GEORGIA TECH RESEARCH CORP ATLANTA


Personal Author(s) : Legg, Keith O ; Rose, Douglas N


Full Text : https://apps.dtic.mil/dtic/tr/fulltext/u2/a169492.pdf


Report Date : 01 Jul 1985


Pagination or Media Count : 37


Abstract : This report details the modifications to an existing ion implanter which were made in order to use it for ion acoustic microscopy. Results are described of tests of the technique on samples of cubic zirconia implanted with nitrogen ions. The utility of the technique for monitoring the progress of implantation in metals and ceramics is discussed. Keywords: Ion acoustic microscopy; photoacoustic microscopy; Thermal wave imaging; Zirconia; Ion Implantation.


Descriptors :   *ION IMPLANTATION , *ACOUSTIC MICROSCOPES , NITROGEN , MICROSCOPY , CERAMIC MATERIALS , INFRARED IMAGES , ACOUSTOOPTICS , ZIRCONIUM OXIDES , FIELD ION MICROSCOPY


Subject Categories : Ceramics, Refractories and Glass
      Test Facilities, Equipment and Methods
      Acoustics