Accession Number : AD1036886


Title :   Shear Bond Strength of Resin Buttons to Lithium Disilicate and Leucite Reinforced Feldspathic Restorations


Descriptive Note : Technical Report


Corporate Author : Uniformed Services University of the Health Sciences Bethesda United States


Personal Author(s) : Mooney,Michael A


Full Text : https://apps.dtic.mil/dtic/tr/fulltext/u2/1036886.pdf


Report Date : 01 May 2016


Pagination or Media Count : 42


Abstract : Purpose: The purpose of this study is to compare the shear bond strength of resin buttons to lithium disilicate (IPS e.max CAD) and leucite reinforced feldspathic restorations (Empress CAD) after different surface preparation techniques. Methods and Materials: Group A,B,C,D, and E are divided by the surface treatments that were applied. IPS e.max CAD crowns were fired in porcelain oven according to manufacturer recommendations. One sample of each group was photographed with scanning electron microscopy (SEM).


Descriptors :   tooth diseases , composite structures , bonding , therapeutics , statistical tests , literature surveys , porcelain , composite materials , flexural strength , dentistry , hydrofluoric acid , teeth , scanning electron microscopy


Subject Categories : Medicine and Medical Research


Distribution Statement : APPROVED FOR PUBLIC RELEASE