Accession Number : AD1034799


Title :   Lab Streaming Layer Enabled Myo Data Collection Software User Manual


Descriptive Note : Technical Report,01 Jan 2017,01 Mar 2017


Corporate Author : US Army Research Laboratory Adelphi United States


Personal Author(s) : Lee,Michael H


Full Text : https://apps.dtic.mil/dtic/tr/fulltext/u2/1034799.pdf


Report Date : 07 Jun 2017


Pagination or Media Count : 32


Abstract : The US Army Research Laboratory conducts research in multimodal human gesture classification using data acquired from various physiological sensors. The Myo armband is one such sensor used for the data collection. A simple Myo Data Collection Software was written to gather all of the data available from the Myo armband (e.g., orientation, gyroscope, accelerometer, and electromyography). This report describes the Myo Data Collection Software background, installation, and operation. An example output comma-separated value file is included as an Appendix.


Descriptors :   application software , user manuals , recording systems , DATA ACQUISITION , BIOENGINEERING , physiology , instrumentation


Subject Categories : Biomedical Instrumentation and Bioengineering
      Anatomy and Physiology


Distribution Statement : APPROVED FOR PUBLIC RELEASE