Accession Number : AD1033237


Title :   Incorporation of a Redfern Integrated Optics ORION Laser Module with an IPG Photonics Erbium Fiber Laser to Create a Frequency Conversion Photon Doppler Velocimeter for US Army Research Laboratory Measurements: Hardware, Data Analysis, and Error Quantification


Descriptive Note : Technical Report,01 Oct 2016,01 Mar 2017


Corporate Author : US Army Research Laboratory Aberdeen Proving Ground United States


Personal Author(s) : Zellner,Michael B ; Schuster,Brian E


Full Text : https://apps.dtic.mil/dtic/tr/fulltext/u2/1033237.pdf


Report Date : 01 Apr 2017


Pagination or Media Count : 18


Abstract : This report addresses benefits and difficulties of integrating a Redfern Integrated Optics ORION laser module with an IPG Photonics Erbium fiber laser to create a frequency-conversion photon Doppler velocimeter. Many of the implications arise from the use of 2 independent laser sources to create the optical beat frequencies measured by the heterodyne system and the associated drift of their center frequencies. This drift was quantified and analysis techniques were developed to actively monitor the drift, in situ, during dynamic measurements. Finally, an example of postprocessing analysis is given, which quantifies the applicable error from using such a system to the overall measurement.


Descriptors :   analyzers , continuous waves , high resolution , shaped charge jets , photons , power meters , spectrum analyzers , photonics , integrated optics , optics , optical fiber lasers , frequency conversion , INTEGRATED OPTICS


Subject Categories : Fiber Optics and Integrated Optics


Distribution Statement : APPROVED FOR PUBLIC RELEASE