Accession Number : AD0712647


Title :   FROST INVESTIGATIONS. FISCAL YEAR 1957. DETERMINATION OF ERRORS IN TEMPERATURE MEASURING EQUIPMENT.


Descriptive Note : Interim rept. no. 1.


Corporate Author : ARCTIC CONSTRUCTION AND FROST EFFECTS LAB BOSTON MASS


Report Date : DEC 1956


Pagination or Media Count : 43


Abstract : A number of relatively elementary tests were run with thermocouples, connectors and potentiometers to determine response characteristics under transient and differential temperature conditions. Results are intended to serve as a guide to observers in obtaining accurate temperature determinations. Under the conditions of the tests, as much as 10 minutes was required before accurate readings could be obtained, while connectors or potentiometers were adjusting to temperature changes. Other effects of temperature differences were also observed. (Author)


Descriptors :   (*TEMPERATURE SENSITIVE ELEMENTS, ERRORS), MEASUREMENT, THERMOCOUPLES, POTENTIOMETERS, TEMPERATURE, RESPONSE, TEST EQUIPMENT, TEST METHODS, STATISTICAL DATA


Subject Categories : SNOW, ICE AND PERMAFROST
      TEST FACILITIES, EQUIPMENT AND METEORS


Distribution Statement : APPROVED FOR PUBLIC RELEASE