Abstract : The panels tested included one each of P/N 12FTB010-1, -2, -3, -4, -4 (painted), and a special fiberglass core panel. Transient temperature response data for these six types of construction revealed: (1) the filling of the fiberglass core with glass microspheres lessened rather than improved the insulation properties; (2) the coating of the phenolic surface with acrylic paint FMS-1004 did not significantly affect the insulation properties; and (3) the best insulation properties were demonstrated by panels 12FTB010-3 and -4. The transient temperature responses of these two panels were essentially equal. (Author)


Descriptors :   *AIRCRAFT PANELS , *HONEYCOMB CORES , THERMAL INSULATION , SANDWICH PANELS , GLASS TEXTILES , JET FIGHTERS , TEST METHODS


Distribution Statement : APPROVED FOR PUBLIC RELEASE