Accession Number : AD0434064


Title :   FLUID TIMER FOR ORDNANCE APPLICATIONS.


Descriptive Note : Quarterly rept. no. 2, 1 Oct-31 Dec 63,


Corporate Author : GENERAL ELECTRIC CO BURLINGTON VT


Personal Author(s) : Krulewich,E B ; Kantola,R A


Report Date : 28 Jan 1964


Pagination or Media Count : 32


Abstract : This report describes the work carried out during the second quarter of a program to develop a fluid timer demoonstrator. The demonstrator uses fluid amplifiers without moving parts.. Activity during the second quarter was concentrated on perfecting the counter and determining the controlling factors behind the oscillator frequency variation with temperature and pressure. Two general approaches for reducting the temperature sensitivity of an oscillator are being investigated. (Author)


Descriptors :   CLOCKS , FLUIDS , AMPLIFIERS , OSCILLATORS , TEMPERATURE , PRESSURE , SENSITIVITY , FREQUENCY , DETERMINATION , FLUID MECHANICS , ORDNANCE


Distribution Statement : APPROVED FOR PUBLIC RELEASE