Accession Number : AD0433805


Title :   PRODUCTION ENGINEERING MEASURE FOR IMPROVED RELIABILITY OF SOLID ELECTROLYTE TANTALUM CAPACITORS.


Descriptive Note : Quarterly rept. no. 2, 30 Sep-29 Dec 63,


Corporate Author : MALLORY (P R) AND CO INC INDIANAPOLIS IND


Personal Author(s) : Smith,A W H


Report Date : 29 Dec 1963


Pagination or Media Count : 36


Abstract : Detailed analysis of the incoming evaluation procedure for tantalum powder was continued. An apparent anomaly in the breakdown voltage test results has become apparent. At the present time, no experimental evidence is available which can throw doubt on the test procedure. A procedure for electrical evaluation of tantalum wire was worked out. Studies of anode fabrication and capacitor assembly were initiated. Wide variances in the in-process breakdown voltage tests was observed. Some specifications were revised in view of the results of dehydration studies and data analysis on the first pilot run samples. (Author)


Descriptors :   *TANTALUM CAPACITORS , MANUFACTURING , ELECTROLYTES , TANTALUM , POWDERS , VOLTAGE , TEST METHODS , PRODUCTION , CATHODES , ANODES