Accession Number : AD0003175


Title :   REMOVAL OF NA2O FROM A NAK SYSTEM USING A NATURAL CIRCULATION COLD TRAP


Descriptive Note : Technical rept.


Corporate Author : MINE SAFETY APPLIANCES CO CALLERY PA


Personal Author(s) : BATUTIS, E F ; WALTERS, S L ; MAUSTELLER, J W


Full Text : https://apps.dtic.mil/dtic/tr/fulltext/u2/003175.pdf


Report Date : 09 Mar 1953


Pagination or Media Count : 14


Abstract : Determinations were made of the bulk density of NaK-Na sub2 O in a cold-trap system utilized for the removal of O from eutectic NaK. The cold trap was no longer effective when the Na sub2 O reached 21% by weight of the cold- trap contents. The average O removal rate was 0.0006 wt-%/hr (46 mg O/hr).


Descriptors :   *PURITY , *LIQUID METAL COOLANTS , DENSITY , LOW TEMPERATURE , REMOVAL , RATES


Subject Categories : Industrial Chemistry and Chemical Processing


Distribution Statement : APPROVED FOR PUBLIC RELEASE